DSpace logo

Please use this identifier to cite or link to this item: http://dspace.bits-pilani.ac.in:8080/jspui/xmlui/handle/123456789/11122
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSharma, Bhupendra Kumar-
dc.date.accessioned2023-08-03T06:49:42Z-
dc.date.available2023-08-03T06:49:42Z-
dc.date.issued2022-11-
dc.identifier.urihttps://journals.sagepub.com/doi/abs/10.1177/09544062221136710-
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/11122-
dc.description.abstractPresent paper deals with the effect of Hall and ion slips on MHD blood flow through a catheterized multi-stenosis artery with thrombosis. Blood is considered a base fluid, and the suspension of Au and GO nanoparticles are used to form the hybrid nano-blood suspension. The hemodynamic mathematical model is presented to mimic the blood flow inside the artery subjected to Joule heating, thermal radiation, Hall and ion slip effects. The effect of the shape of nanoparticles and the variable viscosity depending upon hematocrit is taken into account. The mathematical model is presented in a curvilinear coordinate system, and a mild stenosis assumption is used to get the closed-form solutions. The reduced governing equations are solved using the Crank Nicholson scheme with “MATLAB.” The effect of various pertinent parameters on flow patterns are illustrated graphically. It is observed that increasing the Hall and ion slips parameter causes the increment in the fluid velocity due to an enhancement in the cyclotron frequency of the particles. The hybrid nanoparticles Au-GO/blood has a higher temperature profile than pure blood and unitary nanoparticles, as the thermal conductivity increases with an increase in nanoparticle concentration. Scientists and clinical researchers may find the present study useful in understanding the various illness’s conditions, including cancers, infections, and the removal of blood clots. Furthermore, current research may be helpful in the biomedical area, such as magnetic resonance angiography (MRA), which creates an image of an artery to identify any abnormalities in the artery. The current findings are consistent with recent findings in earlier blood flow research studies.en_US
dc.language.isoenen_US
dc.publisherSageen_US
dc.subjectMathematicsen_US
dc.subjectMATLABen_US
dc.subjectHybrid nanoparticlesen_US
dc.subjectThrombosisen_US
dc.titleHall and ion slip effects on hybrid nanoparticles (Au-GO/blood) flow through a catheterized stenosed artery with thrombosisen_US
dc.typeArticleen_US
Appears in Collections:Department of Mathematics

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.