DSpace logo

Please use this identifier to cite or link to this item: http://dspace.bits-pilani.ac.in:8080/jspui/xmlui/handle/123456789/11162
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSharma, Bhupendra Kumar-
dc.date.accessioned2023-08-04T09:21:04Z-
dc.date.available2023-08-04T09:21:04Z-
dc.date.issued2023-04-
dc.identifier.urihttps://link.springer.com/chapter/10.1007/978-3-031-29959-9_10-
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/11162-
dc.description.abstractThe present study aims to perform computer simulations of two-dimensional hemodynamics of blood flow through an overlapping stenosed artery considering the non-Newtonian Casson fluid model to simulate the arterial region’s hemorheological properties and hematocrit-dependent viscosity to mimic the realistic behavior of blood with a uniform magnetic field applied in the radial direction of the blood flow, motivated by magneto-hemodynamics effects. This study is influenced by drug delivery applications and proposes a mathematical model for unsteady blood flow using hybrid biocompatible nanoparticles (Gold and Copper). The Crank-Nicolson method solves the transformed governing equations with accompanying boundary conditions. For a given critical height of the stenosis, key hemodynamic variables such as velocity, wall shear stress, temperature, and flow rate are computed. The velocity and temperature profiles show enhancement as the Casson fluid parameter (β) increases. The velocity, wall shear stress, and flow rate of the fluid (blood) decline with an increment in the hematocrit parameter (hm). A comparative study with published work is done to validate the current model, which is in good accord with the previous work. The findings may act as a benchmark for formulating the best regimens for the targeted treatment of atherosclerosis, obstructed hemodynamics, nano-hemodynamics, nano-pharmacology, blood purification systems, and treatment of hemodynamic ailments.en_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.subjectMathematicsen_US
dc.subjectHematocrit-dependent viscosityen_US
dc.subjectOverlapping stenosisen_US
dc.subjectAu-Cu/Blood hybrid nanofluiden_US
dc.subjectPulsatile blood flowen_US
dc.titleModelling Pulsatile Blood Flow Using Casson Fluid Model Through an Overlapping Stenotic Artery with Au-Cu Hybrid Nanoparticles: Varying Viscosity Approachen_US
dc.typeArticleen_US
Appears in Collections:Department of Mathematics

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.