Please use this identifier to cite or link to this item:
http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/12965
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ranganayakulu, Chennu | - |
dc.date.accessioned | 2023-11-09T10:08:16Z | - |
dc.date.available | 2023-11-09T10:08:16Z | - |
dc.date.issued | 2017-01 | - |
dc.identifier.uri | https://www.sciencedirect.com/science/article/abs/pii/S1359431116307943 | - |
dc.identifier.uri | http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/12965 | - |
dc.description.abstract | A single-blow transient test technique is employed to measure the Colburn j factor versus Reynolds number characteristics of high efficiency compact heat exchanger surfaces having offset and wavy fins. Using the experimental data, the NTU values are estimated for 5 types of fins. The measured data is evaluated using the maximum slope method to obtain the corresponding heat transfer coefficient in terms of Colburn j factor, and then is compared with the available correlations of theoretical steady state CFD model. In this analysis, the effects of non-adiabatic side walls and longitudinal heat conduction on the exit fluid temperature response and NTU values are discussed. The test core pressure drops are also measured, and the pressure drop components of entrance, acceleration, core friction and exit losses are compared with the CFD results. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.subject | Mechanical Engineering | en_US |
dc.subject | Heat Exchangers | en_US |
dc.subject | CFD | en_US |
dc.title | The single-blow transient testing technique for offset and wavy fins of compact plate-fin heat exchangers | en_US |
dc.type | Article | en_US |
Appears in Collections: | Department of Mechanical engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.