DSpace logo

Please use this identifier to cite or link to this item: http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/15540
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLaskar, Inamur Rahaman-
dc.date.accessioned2024-09-12T03:56:47Z-
dc.date.available2024-09-12T03:56:47Z-
dc.date.issued2024-02-
dc.identifier.urihttps://pubs.rsc.org/en/content/articlehtml/2024/an/d3an02184j-
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/jspui/xmlui/handle/123456789/15540-
dc.description.abstractBased on the explosive nature and harmful effects of nitro-based explosive materials on living beings and the environment, it is extremely important to develop luminescence-based probe molecules for their detection with excellent selectivity and sensitivity. Two AIPE (aggregation-induced phosphorescence emission)-active iridium(III) complexes (M1 and M2) were developed for the sensitive detection of TNT in both contact and non-contact modes. The aggregate solutions of both complexes (M1 and M2 in THF/H2O, 1/9 by volume) detected TNT at the pico-molar (pM) level. These complexes showed greatly enhanced emission intensity while embedded in a PMMA(polymethyl methacrylate) matrix film. The amplified quantum efficiency, improved phosphorescence lifetime, and enhanced porous network of M2-PMMA composite helps to improve the sesitivity of TNT vapor detection. Interestingly, the sensitivity of the detection of TNT by the M2 complex was significantly improved (5-fold) in a PMMA-incorporated complex (CP) with an observed limit of detection (LOD) of 12.8 ppb. From the BET analysis of CP, it was observed that the mesoporous network of CP has an average pore diameter of 8.52 nm and a surface area of 2.03 m2 g−1. The porous network of CP assists in trapping TNT vapor in a polymeric network containing an electron-rich probe (iridium(III) complex, M2), which helps to effectively trap TNT, thus enhancing electronic communication. As a result, significant emission quenching was observeden_US
dc.language.isoenen_US
dc.publisherRSCen_US
dc.subjectChemistryen_US
dc.subjectTNT vaporen_US
dc.subjectMonocyclometalated iridium(III)en_US
dc.titleEnhanced TNT vapor sensing through a PMMA-mediated AIPE-active monocyclometalated iridium(III) complex: a leap towards real-time monitoringen_US
dc.typeArticleen_US
Appears in Collections:Department of Chemistry

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.