Title: | Effect of centred hole angular ribs roughness on the solar collector performance in a square tube |
Authors: | Bhattacharyya, Suvanjan |
Keywords: | Mechanical engineering Rib roughness Solar collector Square channel Inclination angle effects |
Issue Date: | May-2025 |
Publisher: | Inder Science |
Abstract: | The numerical study assessed the heat transfer and pressure drop in an evenly heated square duct with plane and perforated ribs. Working fluid is air with Reynolds number (Re) 10,000-80,000. The pitch ratio (y), the dimensionless spacing between ribs relative to hydraulic diameter, is 0.5, 1.0, and 1.5. Rib inclination angles (θ) from the downstream duct wall range from 30° to 60°. The hole ratio (h) is 0.1 to 0.2, depending on perforation size and hydraulic diameter. In all configurations, the heat transfer improvement is maximum at Re = 10,000 and gradually decreases with rising Re. The thermal performance factors (η) for Re = 10,000 vary between 1.4 and 2.2, depending on configuration. The highest η is found at θ = 60°, y = 0.5, h = 0.2. At Re = 40,000, all configurations have η values over 1. The thermal performance for Re = 80,000 is moderate (η ≈ 1.03) for θ = 60°, y = 0.5, h = 0.2. Other configurations provide lower values that are barely over unity. |
URI: | https://www.inderscienceonline.com/doi/abs/10.1504/PCFD.2025.146021 http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/19880 |
Appears in Collections: | Department of Mechanical engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.