Please use this identifier to cite or link to this item:
http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/9397
Title: | Comparative study between VMD and EMD in bearing fault diagnosis |
Authors: | Gupta, Karunesh Kumar |
Keywords: | EEE Ball Bearing Accelerometer Sensor Variational Mode Decomposition (VMD) Empirical Mode Decomposition (EMD) Fast Fourier Transform (FFT) |
Issue Date: | 2014 |
Publisher: | IEEE |
Abstract: | This paper proposes a novel Variational mode decomposition (VMD) algorithm for bearing fault diagnosis. The Fast Fourier Transform fails to analyse the transient and non-stationary signals. Discrete Fourier transform and Empirical mode decomposition do not have the ability to attain the accurate Intrinsic mode functions under dynamic system fault conditions because the characteristic of exponentially decaying dc offset is not consistent. EMD is a fully data-driven, not model-based, adaptive filtering procedure for extracting signal components. The EMD technique has high computational complexity and requires a large data series. The proposed technique has high accuracy and convergent speed, and is greatly appropriate for bearing fault diagnosis. This paper illustrates that VMD removes the exponentially decaying dc offset and evaluates its performance compared to EMD. |
URI: | https://ieeexplore.ieee.org/document/7036515 http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/9397 |
Appears in Collections: | Department of Electrical and Electronics Engineering |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.