dc.contributor.author |
Shenoy, Meetha V. |
|
dc.date.accessioned |
2023-03-28T09:27:32Z |
|
dc.date.available |
2023-03-28T09:27:32Z |
|
dc.date.issued |
2014 |
|
dc.identifier.uri |
https://ieeexplore.ieee.org/document/7001152 |
|
dc.identifier.uri |
http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/10017 |
|
dc.description.abstract |
This paper deals with the design of a SAR-ADC with 8-bit resolution suited for bio-medical application. The design of the key components of the SAR ADC namely, DAC, Comparator and Sample and Hold circuit (S/H) has been carried out using current mode approach with the DAC operating at sub-threshold regime. The input current range is 10nA to 2.57μA with 10nA as the LSB. The circuit has been designed in UMC 180nm technology Twin-Well Process. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
IEEE |
en_US |
dc.subject |
EEE |
en_US |
dc.subject |
SAR ADC |
en_US |
dc.subject |
Current Mode Design |
en_US |
dc.subject |
Sub-Threshold Operation of DAC |
en_US |
dc.subject |
Current Comparator |
en_US |
dc.subject |
S/H Circuit |
en_US |
dc.title |
A 8-bit SAR ADC using current mode approach for bio-medical applications |
en_US |
dc.type |
Article |
en_US |