DSpace Repository

Energy and exergy analysis of a novel dual-ejector booster transcritical CO2 refrigeration system for applications in warm climates

Show simple item record

dc.contributor.author Dasgupta, Mani Sankar
dc.date.accessioned 2023-09-02T06:29:04Z
dc.date.available 2023-09-02T06:29:04Z
dc.date.issued 2022-09
dc.identifier.uri https://link.springer.com/article/10.1007/s10973-022-11623-x
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/11813
dc.description.abstract This paper presents a thermodynamic analysis of a novel dual-ejector transcritical CO2 refrigeration system for applications in warm climate. Dual-ejector flow-pressurization and flow-splitting for higher ambient temperature operation are implemented to improve the performance. The proposed system is compared with various previously published CO2 systems including B1 (Standard CO2 booster system), B2 (CO2 booster system with parallel compression), B3 (CO2 booster system with flooded LT evaporator), B4 (CO2 booster system with work recovery expander), B5 (CO2 booster system with parallel compression integrated with flooded LT evaporator and work recovery expander) and also with a multi-stage ejector system. The investigation is carried out at ambient temperatures ranging from 34 to 43 °C. Ambient temperature and gas-cooler pressure were found to have a significant effect on the effective flow area of the ejectors. The COP of the proposed system is found to be 32% higher than B5 and 26% higher than the multi-ejector system. Exergy analysis is also carried out to comprehend system response to various parameters including extent of flow-splitting and change in inter-cooler pressure. The ejector Ej-2 was found to have the highest contribution to irreversibility accounting for an increment of 30% with the increase in ambient temperature from 34 to 43 °C. A detailed analysis of the ejector performance is also presented. Mixing chamber diameter is found to be an important parameter affecting the energetic and exergetic performance of the ejector. An enhancement of 29.63% in pressure lift and reduction of 61.11% in the irreversibility contribution of the ejector is possible by increasing the mixing chamber diameter from 0.012 to 0.015 m. en_US
dc.language.iso en en_US
dc.publisher Springer en_US
dc.subject Mechanical Engineering en_US
dc.subject CO2 refrigeration systems en_US
dc.subject Warm climates en_US
dc.title Energy and exergy analysis of a novel dual-ejector booster transcritical CO2 refrigeration system for applications in warm climates en_US