DSpace Repository

Sensing of Stimulus Artifact Suppressed Signals From Electrode Interfaces

Show simple item record

dc.contributor.author Rao, V. Ramgopal
dc.date.accessioned 2023-10-26T03:57:08Z
dc.date.available 2023-10-26T03:57:08Z
dc.date.issued 2015-07
dc.identifier.uri https://ieeexplore.ieee.org/document/7029606
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/12618
dc.description.abstract Stimulus artifacts inhibit reliable acquisition of biological evoked potentials for several milliseconds if an electrode contact is utilized for both electrical stimulation and recording purposes. This hinders the measurement of evoked short-latency biological responses, which is otherwise elicited by stimulation in implantable prosthetic devices. We present an improved stimulus artifact suppression scheme using two electrode simultaneous stimulation and differential readout using high-gain amplifiers. Substantial reduction of artifact duration has been shown possible through the common-mode rejection property of an instrumentation amplifier for electrode interfaces. The performance of this method depends on good matching of electrode-electrolyte interface properties of the chosen electrode pair. A novel calibration algorithm has been developed that helps in artificial matching of impedance and thereby achieves the required performance in artifact suppression. Stimulus artifact duration has been reduced down to 50 μs from the stimulation-cum-recording electrodes, which is ~6× improvement over the present state of the art. The system is characterized with emulated resistor-capacitor loads and a variety of in-vitro metal electrodes dipped in saline environment. The proposed method is going to be useful for closed-loop electrical stimulation and recording studies, such as bidirectional neural prosthesis of retina, cochlea, brain, and spinal cord. en_US
dc.language.iso en en_US
dc.publisher IEEE en_US
dc.subject EEE en_US
dc.subject Stimulus artifact suppression en_US
dc.subject Biphasic constant current stimulator en_US
dc.subject Electrode-electrolyte interface en_US
dc.subject Instrumentation and differential amplifier en_US
dc.title Sensing of Stimulus Artifact Suppressed Signals From Electrode Interfaces en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account