DSpace Repository

Polymer microcantilever biochemical sensors with integrated polymer composites for electrical detection

Show simple item record

dc.contributor.author Rao, V. Ramgopal
dc.date.accessioned 2023-10-28T04:06:57Z
dc.date.available 2023-10-28T04:06:57Z
dc.date.issued 2009-09
dc.identifier.uri https://www.sciencedirect.com/science/article/abs/pii/S1293255809002258
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/12693
dc.description.abstract Micro fabricated sensors based on nanomechanical motion with piezoresistive electrical readout have become a promising biochemical sensing tool. The conventional microcantilever materials are mostly silicon-based. The sensitivity of the sensor depends on Young's modulus of the structural material, thickness of the cantilever as well as on the gauge factor of the piezoresistor. UV patternable polymers such as SU-8 have a very low Young's modulus compared to the silicon-based materials. Polymer cantilevers with a piezoresistive material having a large gauge factor and a lower Young's modulus are therefore highly suited for sensing applications. In this work, a spin coatable and photopatternable mixture of carbon black (CB) and SU-8, with proper dispersion characteristics, has been demonstrated as a piezoresistive thin film for polymer microcantilevers. Results on percolation experiments of SU-8/CB composite and fabrication of piezoresistive SU-8 microcantilevers using this composite are presented. With our controlled dispersion experiments, we could get a uniform piezoresistive thin film of thickness less than 1.2 μm and resistivity of 2.7 Ω cm using 10 wt% of CB in SU-8. The overall thickness of the SU-8/composite/SU-8 is approximately 3 μm. We further present results on the electromechanical characterization and biofunctionalization of the cantilever structures for biochemical sensing applications. These cantilevers show a deflection sensitivity of 0.55 ppm/nm. Since the surface stress sensitivity is 4.1 × 10−3 [N/m]−1, these cantilevers can well be used for detection of protein markers for pathological applications. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject EEE en_US
dc.subject Microcantilevers en_US
dc.subject Electrical detection en_US
dc.subject Sensors en_US
dc.title Polymer microcantilever biochemical sensors with integrated polymer composites for electrical detection en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account