DSpace Repository

Efficiency Enhancement of Multi-Stage Depressed Collector Using an External Magnet in TWTs

Show simple item record

dc.contributor.author Sarkar, Niladri
dc.date.accessioned 2024-02-21T04:04:17Z
dc.date.available 2024-02-21T04:04:17Z
dc.date.issued 2022-11
dc.identifier.uri https://ieeexplore.ieee.org/abstract/document/9902967/keywords#keywords
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/jspui/xmlui/handle/123456789/14390
dc.description.abstract The dependence of overall traveling-wave tube (TWT) efficiency on the collector efficiency is of paramount importance. The objective of achieving high overall efficiency drives us to design a multi-stage depressed collector (MDC) with the theoretically highest possible efficiency with appropriate depressed potentials. Various design parameters, namely electrode geometry, depressed potentials, material parameters, etc., can be optimized to attain the desired theoretical maximum collector efficiency. But in a practical situation, the measured MDC efficiency is relatively less than the designed efficiency, which may be attributed to approximations involved in the nonlinear interaction of the electron beam and RF wave, fabrication inaccuracies, process limitations, simulation approximations, etc. This inexplicable practical decrease in MDC efficiency is typically accompanied by an increase in the backstreaming of electrons into the interaction structure. To compensate for this decrease, a permanent magnet has been suitably positioned on the base plate of the MDC, which results in an increase in collector efficiency. Simulation studies have been carried out to optimize the parameters of the magnet in terms of the geometrical dimensions, position, and magnetic field value, and has been validated experimentally. This technique of collector efficiency enhancement using an external magnet has proven to be very effective, contributing to a significant collector efficiency enhancement of > 5% from ~78% to ~83%, which in turn corresponds to an overall tube efficiency improvement of ~5.8% from 50.5% to 56.3%. en_US
dc.language.iso en en_US
dc.publisher IEEE en_US
dc.subject Physics en_US
dc.subject Collector efficiency en_US
dc.subject External magnetic field en_US
dc.subject Multi-stage depressed collector en_US
dc.subject Traveling-wave tube en_US
dc.title Efficiency Enhancement of Multi-Stage Depressed Collector Using an External Magnet in TWTs en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account