Abstract:
Vibration caused by rotor unbalance is one of the most pertinent problems facing the rotating machines, including electrical motors and turbo machinery among others. Thus vibration attenuation has become very essential in improving the overall performance of such machines. In this paper, a 12-pole radial Active Magnetic Bearing (AMB), using AC excitation has been proposed to counteract the unbalance. Here a switching variation of AMB teeth excitation currents is implemented to generate a rotating force, synchronous with the rotor unbalance but in opposite direction.