Tests and numerical behavior of circular concrete-filled double skin steel tubular stub columns under eccentric loads

Show simple item record

dc.contributor.author Kumar, Manoj
dc.date.accessioned 2024-09-21T04:21:25Z
dc.date.available 2024-09-21T04:21:25Z
dc.date.issued 2023-11
dc.identifier.uri http://www.techno-press.org/content/?page=article&journal=sem&volume=88&num=3&ordernum=8
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/jspui/xmlui/handle/123456789/15687
dc.description.abstract This article describes experimental and numerical analyses of eccentrically loaded over the axially loaded circular concrete filled double-skinned steel tubular (CFDST) short columns. Tests on circular CFDST short columns under eccentric and concentric loading were conducted to assess their responses to the frequent intensity of 5–30 mm at the interval of each 5 mm eccentric loading conditions with constant cross-sectional proportions and width-to-thickness ratios of the outside and internal tubes. The non-linear finite-element analysis of circular CFDST short columns of eccentrically loaded over the axially loaded was performed using the ABAQUS to predict the structural behavior and compare the concentric loading capacity over the various eccentric loading conditions. The comparison outcomes show that the axial compressive strength of the circular CDFST short columns was 2.38–32.86%, lesser than the concentrically loaded short column with the inner circular section. Also, the influence of computer simulation employed is more efficient in forecasting the experimentally examined performance of circular CFDST stub columns. en_US
dc.language.iso en en_US
dc.publisher Techno-Press en_US
dc.subject Civil Engineering en_US
dc.subject Composite actions en_US
dc.subject Concrete-filled double skinned steel tubes (CFDST) en_US
dc.subject Double tube en_US
dc.subject Finite element method en_US
dc.subject Non-linear analysis en_US
dc.title Tests and numerical behavior of circular concrete-filled double skin steel tubular stub columns under eccentric loads en_US