DSpace Repository

Application of HEM11δ Mode in DR based Linear Displacement Sensor

Show simple item record

dc.contributor.author Kumar, A. V. Praveen
dc.date.accessioned 2024-12-13T06:41:34Z
dc.date.available 2024-12-13T06:41:34Z
dc.date.issued 2023
dc.identifier.uri https://ieeexplore.ieee.org/abstract/document/10176341
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/16607
dc.description.abstract Presented a numerical investigation on the application of HEM 11δ mode in a dielectric resonator (DR) sensor. A simple two-port network is implemented by placing two microstrip lines opposite to each other for full transmission. A dielectric resonator (DR) is placed between them to detect the coupling w.r.to its displacement. Proposed transmission mode operated DR excite HEM 11δ mode at~ 3.7 GHz. Here, the DR positional movement produces identical results in both directions (+dx/ -dx) due to the structural bisymmetry. This single frequency operated Transmission circuit provides 1.78 dB/mm sensitivity in the 0 - 9 mm range. en_US
dc.language.iso en en_US
dc.publisher IEEE en_US
dc.subject EEE en_US
dc.subject Dielectric resonator en_US
dc.subject Transmission mode en_US
dc.subject Displacement sensor en_US
dc.title Application of HEM11δ Mode in DR based Linear Displacement Sensor en_US
dc.type Article en_US