DSpace Repository

Bio-Interface Analysis and Detection of Aβ using GaN HEMT-based Biosensor

Show simple item record

dc.contributor.author Taliyan, Rajeev
dc.date.accessioned 2025-03-10T07:02:41Z
dc.date.available 2025-03-10T07:02:41Z
dc.date.issued 2024
dc.identifier.uri https://iopscience.iop.org/article/10.1149/1945-7111/ad2cbc/meta
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/18231
dc.description.abstract Early detection, prognosis, and diagnosis of devastating neurological disorders such as TBI and AD are crucial for developing treatment strategies, efficient patient outcomes, and management in biomedical fields. The work reports the design, development, suitability analysis, and validation of a label-free GaN HEMT-based biosensing platform for the non-invasive detection of FDA-approved biomarker Aβ in saliva sample concentration ranges. The biofunctionalization assay has been validated with both electrical and FTIR spectroscopy-based measurements. A comparative analysis with ELISA assay shows good agreement with ∼2.0% measurement errors demonstrating platform stability and accuracy for Aβ detection. The platform offers a peak sensitivity of 27.20 μA/pg ml−1, 19.10 μA pg−1 ml−1, and 1.48 μA/pg ml−1 for detection in saliva, serum, and CSF concentration ranges with high specificity, excellent repeatability, and reproducibility of the results. The platform offers a sensitivity of 2.40 μA/pg ml−1, 15.40 μA pg−1 ml−1, and 27.20 μA/pg ml−1 for Sbias of 1.0 V, 3.3 V, and 5.0 V respectively. The key biosensor features include fast detection with a response time of 5–10 s and a low sample volume requirement of ∼1–2 μl. The platform comparison with ELISA shows a similar and acceptable linearity trend. A novel equation has been established for ELISA and developed platform-based detection for possible detection accuracy and validation useful for correlating the sensor response with ELISA test results and vice-versa for any target Aβ concentrations. To the best of our knowledge, this is the first time reporting of Aβ detection using a GaN HEMT-based biosensing platform. en_US
dc.language.iso en en_US
dc.publisher IOP en_US
dc.subject Pharmacy en_US
dc.subject Ultra-high sensitivity en_US
dc.subject Biofunctionalization assay validation en_US
dc.subject Serum sample en_US
dc.title Bio-Interface Analysis and Detection of Aβ using GaN HEMT-based Biosensor en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account