DSpace Repository

An assessment of residual stresses and micro-structure during single point incremental forming of commercially pure titanium used in biomedical applications

Show simple item record

dc.contributor.author Kumar, Gulshan
dc.date.accessioned 2025-10-07T10:11:19Z
dc.date.available 2025-10-07T10:11:19Z
dc.date.issued 2020
dc.identifier.uri https://www.sciencedirect.com/science/article/pii/S2214785320327620
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/19653
dc.description.abstract Single point incremental forming (SPIF) is a branch of incremental sheet forming where a very small portion of the sheet is deformed plastically at any moment. The highly localized point deformation is done by a simple hemispherical tool, whose path is numerically monitored by a Computer numerical control (CNC) machine, performs this progressive extremely localized deformation. Since no die is required during forming, highly customized and user-oriented sheet metal products can be manufactured employing the process. SPIF can be readily employed in the manufacturing of customized orthopaedic implants and braces, e.g., cranial implants, ankle implants, elbow and knee support braces. The forming of these sheets through SPIF would results in the generation of residual stresses in the sheet metal. With time and other physical factors, these residual stresses would be relieved resulting in dimensional inaccuracy. This inaccuracy is highly detrimental in the case of implants and highly undesirable for supporting braces. The objective of this work is to investigate, experimentally, the state and magnitude of residual stresses on commercially pure titanium grade 2 by SPIF for biomedical applications. The important process parameters: forming angle and incremental step depth are used for this investigation in the present study. The X-ray diffraction technique was used for the experimental measurements of the residual stresses. Microstructural behaviour of the final product at different incremental step depth and forming angles are also observed by EBSD (Electron backscattered diffraction) technique. The experimental findings showed the formation of increased tensile residual stresses with an increase in incremental step depth and steepness of forming angles. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject Mechanical engineering en_US
dc.subject Residual stresses en_US
dc.subject Titanium grade-2 en_US
dc.subject Microstructure en_US
dc.subject X-Ray diffraction (XRD) en_US
dc.title An assessment of residual stresses and micro-structure during single point incremental forming of commercially pure titanium used in biomedical applications en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account