DSpace Repository

Thermodynamic analysis of cascade refrigeration system using R1234yf-CO2, R1234yf-R410a, and R1234yf-R134a refrigerants

Show simple item record

dc.contributor.author Ranganayakulu, Chennu
dc.contributor.author Bhattacharyya, Suvanjan
dc.date.accessioned 2025-10-22T10:56:37Z
dc.date.available 2025-10-22T10:56:37Z
dc.date.issued 2025-05
dc.identifier.uri https://link.springer.com/article/10.1007/s10973-025-14308-3
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/19868
dc.description.abstract The Kyoto and Montreal Protocols emphasized the necessity of replacing hydrochlorofluorocarbons and chlorofluorocarbons because of their detrimental effects on the ozone layer in the atmosphere, which shields the planet from ultraviolet radiation. Hydrofluorocarbon refrigerants, which do not disrupt the ozone layer, were inspired by all these incidents. The thermodynamic analysis of a cascade refrigeration system was examined in this work utilizing three new refrigerant pair combinations: R1234yf-CO2, R1234yf-R410, and R1234yf-R134a. Numerous operating characteristics, including compressor work, isentropic efficiency, condenser temperature, and evaporator temperature, as well as the coefficient of performance, energy efficiency ratio, and refrigerant mass flow ratio, have been examined and documented. The numerical investigation shows that with an evaporating temperature increase, there is an increase in COP, and the irreversibility of the system decreases. When there is an increase in condenser temperature, COP will decrease, and the irreversibility of the system increases. Thermodynamic analysis shows that out of three refrigerant pairs R1234yf-CO2, R1234yf-R410, and R1234yf-R134a, the COP of R1234yf-R134a refrigerant pair is 28.10% more than the refrigerant pair R1234yf-CO2 and 8.08% more than the refrigerant pair R1234yf-R410. en_US
dc.language.iso en en_US
dc.publisher Springer en_US
dc.subject Mechanical engineering en_US
dc.subject Kyoto and montreal protocols en_US
dc.subject Hydrofluorocarbon refrigerants en_US
dc.subject Cascade refrigeration system en_US
dc.subject Coefficient of performance (COP) en_US
dc.title Thermodynamic analysis of cascade refrigeration system using R1234yf-CO2, R1234yf-R410a, and R1234yf-R134a refrigerants en_US
dc.type Article en_US