DSpace Repository

ANN based approach for selective detection of breath acetone by using hybrid GO-FET sensor array

Show simple item record

dc.contributor.author Ajmera, Pawan K.
dc.contributor.author Hazra, Arnab
dc.date.accessioned 2023-03-14T05:30:14Z
dc.date.available 2023-03-14T05:30:14Z
dc.date.issued 2022-04
dc.identifier.uri https://iopscience.iop.org/article/10.1088/2631-8695/ac6487/meta
dc.identifier.uri http://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/9682
dc.description.abstract This research used hybrid graphene oxide (GO) field effect transistors (FETs) based sensor array to design an electronic nose (e-nose) for identifying exhaled breath acetone to diagnose diabetes mellitus through noninvasive route. Six back gated FET sensors were fabricated with hybrid channel of GO, WO3 and noble metals (Au, Pd and Pt) nanoparticles. The experiment was carried out by using four distinct forms of synthetic breath, each with a different level of interference. Linear discriminant analysis (LDA) and artificial neural networks (ANN) were utilized to classify and analyze the sensor response vector. In contrast, partial least square (PLS) and multiple linear regression (MLR) were used to evaluate the exact acetone concentration in synthetic breath. First, LDA was used to lower the dimensionality of the response vector, which was then provided as an input to the ANN model. ANN was performed with ten perceptrons model in the hidden layer and highest accuracy of 99.1% was achieved. Additionally, by using the loading plot of PLS, three sensors (Pt/WO3/GO, Pd/WO3/GO, and WO3/GO) had the ample use to predict the concentration of breath acetone. Moreover, the MLR approach with correlation coefficient (R2) of 0.9572 and root mean square error (RMSE) of 5.63% were used for obtaining the exact concentration of acetone. Consequently, e-nose with matrix of hybrid GO-FET sensors and pattern recognition algorithms (LDA, ANN, PLS and MLR) exhibited considerable ability in selective detection of acetone in synthetic breath. en_US
dc.language.iso en en_US
dc.publisher IOP en_US
dc.subject EEE en_US
dc.subject Hybrid graphene oxide (GO) en_US
dc.subject GO-FET sensor array en_US
dc.title ANN based approach for selective detection of breath acetone by using hybrid GO-FET sensor array en_US
dc.type Article en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account