Item Efficient Variable Air Volume Air Conditioning System Based on Fuzzy Logic Control for Buildings(STA, 2009-03) Parameshwaran, R.A variable air volume (VAV) system is highly preferred to be an energy efficient airconditioning scheme in modern heating, ventilation and air conditioning (HVAC)applications. Based on the energy consumption characteristics, VAV systems are fastreplacing constant air volume (CAV) systems and are capable of maintaining the thermalcomfort for varying load conditions. Fuzzy logic controllers (FLC) are highly preferred ratherthan conventional controllers since FLC exhibits reduced peak overshoot that is observedunder transient conditions of the system. FLC has the capability of controlling the systemprecisely with the set points defined. This paper describes the thermal comfort and energyconservation potential of the VAV system utilizing a fuzzy logic controller (FLC) thatenhances the system performance substantially. A simple VAV building model wasdeveloped and the energy utilization of the VAV system has been experimentallyinvestigated. Input data for fuzzy logic are zone temperature and duct static pressure and theoutput is supply air fan speed. Experimental results show that the energy saving potential ofthe VAV system was 27% at part load conditions, compared with the CAV system.Experimental results express that the required thermal comfort was achieved using FLC.Item Experimental Evaluation of Combined DCV and Economizer Cycle using a FLC Variable Air Volume (VAV) System(Taylor & Francis, 2016) Parameshwaran, R.A healthy indoor environment with sufficient fresh air is a prerequisite for the well-being and high productivity of building occupants. Carbon dioxide (CO2) based Demand Controlled Ventilation (DCV) optimizes and resolves the traditional conflict between reducing ventilation to save energy while maintaining adequate ventilation for air quality. Therefore, in conditioned spaces where occupancy levels vary, CO2based DCV can prove to be an energy efficient method for meeting ventilation needs while maintaining good IAQ. Furthermore, an economizer cycle can be used to save cooling energy. This design scheme takes advantage of cool weather conditions to supplement or satisfy the cooling load. When a Proportional-Integral-Derivative (PID) controller is used, it can respond only to linear variations using single input and single output operations. This can be improved by using a Fuzzy Logic Controller (FLC). This paper deals with the energy savings in a VAV air conditioning system achieved by combining DCV with an air conditioning economizer cycle incorporating FLC. The CO2 concentration and outside temperature are taken as input and damper angle as output for the FLC. Both laboratory measurements and simulations were made. Simulation was undertaken using MATLAB-Simulink. The potential energy savings of DCV combined with a temperature economizer cycle is in the range of 28% to 79% for VAV systems and 19% to 42% for CAV systems. The Indoor Air Quality (IAQ) is also maintained. An experimental test rig was developed and used to verify the performance of the system. This experimental work has been conducted to obtain the system’s response for design outdoor conditions.