A 8-bit SAR ADC using current mode approach for bio-medical applications

dc.contributor.authorShenoy, Meetha V.
dc.date.accessioned2023-03-28T09:27:32Z
dc.date.available2023-03-28T09:27:32Z
dc.date.issued2014
dc.description.abstractThis paper deals with the design of a SAR-ADC with 8-bit resolution suited for bio-medical application. The design of the key components of the SAR ADC namely, DAC, Comparator and Sample and Hold circuit (S/H) has been carried out using current mode approach with the DAC operating at sub-threshold regime. The input current range is 10nA to 2.57μA with 10nA as the LSB. The circuit has been designed in UMC 180nm technology Twin-Well Process.en_US
dc.identifier.urihttps://ieeexplore.ieee.org/document/7001152
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/10017
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.subjectEEEen_US
dc.subjectSAR ADCen_US
dc.subjectCurrent Mode Designen_US
dc.subjectSub-Threshold Operation of DACen_US
dc.subjectCurrent Comparatoren_US
dc.subjectS/H Circuiten_US
dc.titleA 8-bit SAR ADC using current mode approach for bio-medical applicationsen_US
dc.typeArticleen_US

Files