New approach to improve COP and heat recovery in transcritical CO2 refrigeration system for milk processing application

No Thumbnail Available

Date

2025-02

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Nature

Abstract

In hot climates, subcooling or after-cooling is an effective method to enhance the coefficient of performance (COP) of CO2 transcritical refrigeration system. This study investigates improvement of two contemporary subcooling arrangements: Integrated mechanical subcooling (IMS) and dedicated mechanical subcooling (DMS) and evaporative cooling arrangement to gascooler by introduction of gravity-fed evaporator in a dual evaporator parallel compression system suitable for milk processing. Using location-specific average meteorological data, the performance of the proposed systems is evaluated for Pune, India. Comparative analysis is conducted against a baseline transcritical CO2 system with flash gas bypass but lacking any subcooling arrangement. A considerable improvement in COP is observed when subcooling is combined with parallel compression. Incorporation of evaporative cooling with parallel compression yields 62.3% improvement in COP over the flash gas bypass system. However, heat recovery potential is considerably reduced by adopting evaporative cooling. Additionally, the study quantifies a potential reduction in water consumption of 45.6% over a system using flash gas bypass with an indirect evaporative cooling arrangement, and a reduction of 34.3% over a system employing parallel compression with a split gas cooler indirect evaporative cooling arrangement.

Description

Keywords

Mechanical engineering, CO2 transcritical refrigeration, Mechanical subcooling systems, Evaporative cooling performance, Milk processing energy efficiency

Citation

Endorsement

Review

Supplemented By

Referenced By