Role of Injection Barrier in Capacitance-Voltage Measurements of Organic Devices

dc.contributor.authorRao, V. Ramgopal
dc.date.accessioned2023-10-26T05:12:26Z
dc.date.available2023-10-26T05:12:26Z
dc.date.issued2014-05
dc.description.abstractCapacitance-voltage (C-V) measurements represent a very useful technique, however, its usage in organic devices has been a subject of debate because of the role played by the ambient-induced unintentional doping. In this letter, we show that, contrary to the current understanding, prolonged ambient exposure does not significantly increase the unintentional doping density of organic semiconductors (OSCs). Our C-V measurements and detailed numerical simulations clearly indicate that the observed dispersion in C-V characteristics can be attributed to the variation in the carrier injection barrier at the OSC/electrode interface. An analytical relation between the injection barrier and the response time is derived to describe the C-V characteristics of organic devices.en_US
dc.identifier.urihttps://ieeexplore.ieee.org/document/6784309
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/12629
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.subjectEEEen_US
dc.subjectPentaceneen_US
dc.subjectCapacitanceen_US
dc.subjectInjection Barrieren_US
dc.subjectOrganic field effect transistors (OFETs)en_US
dc.titleRole of Injection Barrier in Capacitance-Voltage Measurements of Organic Devicesen_US