On the design and fabrication of polyvinylidene fluoride-based sensors to detect recurrence of diaphragmatic hernia

dc.contributor.authorKala, Prateek
dc.date.accessioned2025-10-10T04:37:12Z
dc.date.available2025-10-10T04:37:12Z
dc.date.issued2024-12
dc.description.abstractPolyvinylidene fluoride (PVDF) bio-sensors have gained potential interest in remote health monitoring of patients using Internet of Things (IoT) technologies. But hitherto, limited studies have reported on the fabrication of PVDF-hydroxyapatite (HAP)-chitosan (CS) based sensors processed through two different processing routes from a process suitability viewpoint to determine the recurrence of diaphragmatic hernia (DH). The sensors fabricated in this study comprise three layers, that is, a substrate (dielectric material), a metallic patch, and a ground plane that works on the microstrip patch antenna (MPA). Two manufacturing approaches have been followed in this study for the fabrication of the dielectric substrate: material extrusion (MEX) and gel-casting. Primarily, PVDF (90%) -HAP (8%) -CS (2%) has been selected for the sample preparation, following that different characterizations have been performed on the chosen composition to ensure its suitability for sensor fabrication. The simulated results were extracted in the form of return loss (S11) versus radiating frequency (fr), specific absorption rate (SAR) field, electric (E), and magnetic (H) field variables. Following that, the substrates were fabricated through the MEX and gel-casting approach, and Cu tape was used to make the conducting parts of the sensor. The sensor’s radio-frequency (RF) behaviour was tested on a vector network analyser (VNA) to obtain the output of S11 versus fr. The RF-characteristic of the sensors fabricated through MEX and gel-casting approaches represent that the sensors designed for dielectric constant (εr) = 9.61 resonate at 2.72 GHz for MEX and 2.67 GHz for gel-casting while possessing the S11of −14.14 and −28.40 dB respectively.en_US
dc.identifier.urihttps://journals.sagepub.com/doi/abs/10.1177/09544062241305986
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/jspui/handle/123456789/19712
dc.language.isoenen_US
dc.publisherSageen_US
dc.subjectMechanical engineeringen_US
dc.subjectPVDF bio-sensorsen_US
dc.subjectIoT health monitoringen_US
dc.subjectGel-casting and material extrusionen_US
dc.subjectMicrostrip patch antennaen_US
dc.titleOn the design and fabrication of polyvinylidene fluoride-based sensors to detect recurrence of diaphragmatic herniaen_US
dc.typeArticleen_US

Files