Characterization of power losses of a soiled PV panel in Shekhawati region of India

dc.contributor.authorKumar, Rajneesh
dc.date.accessioned2023-03-03T09:24:49Z
dc.date.available2023-03-03T09:24:49Z
dc.date.issued2016-06
dc.description.abstractThis paper introduces a model that quantifies the relationship between power output, incident irradiance and soil particle size composition of soiled photovoltaic panels. Soil samples used in artificial soiling experiments were collected from Shekhawati region in India and their relative percentage of standard particle sizes is determined from sieve analysis. A non-linear relationship between irradiance and power is obtained using regression analysis showing the effect of particle size composition present on the panel. Further, the tilt angle for maximum power extraction is determined for each soiled panel and the deviation from the optimum tilt angle of a clean panel is observed. It is concluded that, when the soil present on the panel is rich in the particles with diameter (75 μm and below), the deviation from the tilt angle of a clean panel is 4°, however if the soil contains higher composition of both 150 μm and 300 μm particle sizes the deviation is 8°.en_US
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0038092X16001407
dc.identifier.urihttp://dspace.bits-pilani.ac.in:8080/xmlui/handle/123456789/9471
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectEEEen_US
dc.subjectIrradianceen_US
dc.subjectParticle size compositionen_US
dc.subjectRegressionen_US
dc.subjectSoilingen_US
dc.subjectTilt angleen_US
dc.titleCharacterization of power losses of a soiled PV panel in Shekhawati region of Indiaen_US
dc.typeArticleen_US